HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
System Fan
1-4-8 HP_DeviceIndication: Fan Redundancy Lost
Table 8-28 HP_DeviceIndication: Fan Redundancy Lost
Property name
Property implementation
AlertingManagedElement WBEM path of the SMX_FanRedundancySet instance
representing the redundancy set where redundancy
was lost.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
6
ProviderName
HP Cooling
RecommendedActions
Check the fan configuration and check the status of the
cooling redundancy. Ensure the system is being cooled
adequately. Add or replace fans if necessary.
HP_AlertIndication
Summary
Cooling redundancy lost
EventCategory
23 (System Cooling)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription
Cooling Redundancy has been Lost
1-4-9 HP_DeviceIndication: Fan Redundancy
Restored
Table 8-29
HP_DeviceIndication: Fan Redundancy Restored
Property name
Property implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description Cooling redundancy for the system has been restored.
(Redun dancySetCaption), where
RedundancySetCaption is SMX_FanRedundancySet.
Caption of the cooling redundancy set with restored
redundancy
AlertingManagedElement WBEM path of the SMX_FanRedundancySet instance
representing the cooling redundancy set with restored
redundancy
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
8