HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
System Fan
1-4-4 HP_SensorHardwareIndication: Fan Failed
Table 8-24 HP_SensorHardwareIndication: Fan Failed
Property name
Property implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description A fan has failed. Please check the failed fan and
replace if necessary. (FanCaption), where FanCaption
is
the SMX_Fan.Caption for the fan that has failed
AlertingManagedElement WBEM path of the SMX_Fan instance representing the
failed fan
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
3
ProviderName
HP Cooling
RecommendedActions
Please check the failed fan and replace if necessary.
HP_AlertIndication
Summary
Fan failed
EventCategory
23 (System Cooling)
ProbableCause
94 (Fan Failure)
ProbableCauseDescription
Fan Failed
1-4-5 HP_SensorHardwareIndication: Fan Repaired
Table 8-25
HP_SensorHardwareIndication: Fan Repaired
Property name
Property implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description A fan has been repaired. The fan is now operating
properly. (FanCaption), where FanCaption is the
SMX_Fan.Caption for the fan that has been repaired
AlertingManagedElement WBEM path of the SMX_Fan instance representing the
failed fan
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)