HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
System Fan
Table 8-19 Class: SMX_SystemFanSensor
Property name
Property implementation
GroupComponent
References HP_ComputerSystem
PartComponent
References HP_FanSpeedSensor
1-3-19 SMX_AssociatedFanSensor
The SMX_AssociatedFanSensor class implements the HP_AssociatedFanSensor class and associates
the HP_FanSpeedSensor instance with HP_Fan instances.
Table 8-20 Class: SMX_AssociatedFanSensor
Property name
Property implementation
Antecedent
References HP_FanSpeedSensor
Dependent
References HP_Fan
1-4 Supported indications
1-4-1 Provider Indication Common Properties
The following table describes the properties that are common to all of the SMX Fan Provider
indications that are implemented for server platforms, where available.
Table 8-21 Provider Indication Common Properties
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of the indication
IndicationTime
Time of indication
CIM_AlertIndication
EventTime Time of the event or time of the indication if event time
unknown
SystemName
SMX_ComputerSystem.Name
SystemCreationClassName
SMX_ComputerSystem.CreationClassName
HP_AlertIndication
ProviderVersion Provider Version in the format VV.UU.FF. for example,
01.05.00
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication