HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

System Fan
Table 8-18 Class: SMX_FanSpeedSensor
Property name
Property implementation
ElementName Short description of this fan speed sensor from the
name displayed by the MP or iLO and the location.
For example: Fan speed sensor for Fan 1 at
CabinetFan=01
CIM_Managed SystemElement
OperationalStatus[0]
2 (OK) if fan sensor is operating properly;
StatusDescriptions[0] Fan sensor is operating properly if
OperationalStatus[0] is 2 (OK);
HealthState
5 (OK) if fan sensor is operating properly;
Name Name of this fan speed sensor from the name
displayed by the MP or iLO and the location.
For example: Fan speed sensor for Fan 1 at
CabinetFan=01
CIM_LogicalDevice
CreationClassName
SMX_FanSpeedSensor
DeviceID
Unique identifier for this fan slot
SystemCreationClassName HP_ComputerSystem.CreationClassName
SystemName HP_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_Sensor
SensorType
5 (Tachometer)
CurrentState
“Normal”
PossibleStates Array can contain any of the following values:
PossibleStates[0] = “Normal”
CIM_NumericSensor
CurrentReading
Current reading of fan speed sensor
BaseUnits 19 (RPM)
65 (Percentage)
RateUnits
0 (None)
UnitModifier
0
1-3-18 SMX_SystemFanSensor
SMX_SystemFanSensor class implements the HP_SystemFanSensor class and associates the
HP_ComputerSystem instance with HP_FanSpeedSensor.