System Fan
Table 8-13 Class: SMX_SystemPhysicalFan
Property name
Property implementation
GroupComponent
References HP_ComputerSystemChassis
PartComponent
References HP_FanModule
1-3-13 SMX_RealizesFan
The SMX_RealizesFan class implements the HP_RealizesFan class and associates the HP_Fan instance
with HP_FanModule instances.
Table 8-14 Class: SMX_RealizesFan
Property name
Property implementation
Antecedent
References HP_FanModule
Dependent
References HP_Fan
1-3-14 SMX_FanSlot
SMX_FanSlot is used to model physical fan slots on Servers.
Table 8-15 Class: SMX_FanSlot
Property name
Property implementation
CIM_ManagedElement
Caption Short description of this fan slot from the name
displayed by the MP or iLO and the location.
For example: Fan 1 at CabinetFan=01
Description Description of the fan slot, For example: Fan 1 at
CabinetFan=01
ElementName Name of the fan slot, For example: Fan 1 at
CabinetFan=01
CIM_Managed SystemElement
OperationalStatus[0]
2 (OK) – if fan slot is operating properly;
StatusDescriptions[0] Fan slot is operating properly – if OperationalStatus[0]
is 2 (OK);
HealthState
5 (OK) – if fan is operating properly;
Name
Name of the fan slot, Fan 1 at CabinetFan=01
CIM_PhysicalElement
CreationClassName
SMX_FanSlot
Tag
Unique identifier for this fan slot
CIM_PhysicalPackage
ConnectorLayout
6 (Slot)