HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Smart Array v2.7
1-4-23 HP_DeviceIndication: Enclosure Fan status
changed to Degraded
Table 1-28 HP_DeviceIndication: Enclosure Fan status changed to Degraded
Property name
Property implementation
DeviceModel
Enclosure Model string
1-4-24 HP_DeviceIndication: Enclosure Fan status
changed to Failure
Table 1-29
HP_DeviceIndication: Enclosure Fan status changed to Failure
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (major)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan status changed to a status of
Failure. An enclosure has detected a failure in the fan
subsystem and there is insufficient fan capability to
ensure normal operation.
AlertingMangedElement
WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
306
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SmartArray
RecommendedActions Verify that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Fan status error