HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Smart Array v2.7
1-4-23 HP_DeviceIndication: Enclosure Fan status
changed to Degraded
Table 1-28 HP_DeviceIndication: Enclosure Fan status changed to Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan status changed to a status of
Degraded. An enclosure has detected there may a
problem with one or more of the fans.
AlertingMangedElement
WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
305
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SmartArray
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Fan Status changed to Degraded.
EventCategory
24 (Primary Storage Cooling)
ProbableCause
94 (Fan failure)
ProbableCauseDescription
Fan Degraded
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>