HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

Smart Array v2.7
1-4-22 HP_DeviceIndication: Enclosure Fan status
changed to OK
Table 1-27 HP_DeviceIndication: Enclosure Fan status changed to OK
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan status changed from a status
of Non-OK to a status of OK.
AlertingMangedElement
WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
304
EventTime Time of the event or time of the indication if event time
is unknown
ProviderName
HP SmartArray
RecommendedActions
No action required
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Fan Status OK
EventCategory
24 (Primary Storage Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription
Fan Status Changed to OK
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
OSType
SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion
For example 2.2.0.0
SystemFirmwareVersion Firmware version of the computer system generating
the indication