HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Smart Array v2.7
1-4-15 HP_DeviceIndication: Controller Cache status—
Permanently Disabled
Table 1-20
HP_DeviceIndication: Controller Cache status—Permanently Disabled
Property name
Property implementation
VariableTypes[] String (1)
uint32 (5)
VariableValues[] FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
1-4-16 HP_DeviceIndication: Enclosure Power Supply
status changed to Non Redundant
Table 1-21 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description Storage Enclosure Power Subsystem status has
changed to a Non Redundant Status
AlertingMangedElement
WBEM path of the SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
301
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SmartArray
RecommendedActions Check status of all enclosure power supplies. Problem
may be caused by a failed power supply. Add or
replace power supplies as necessary.
SystemName
Name of the computer system generating the indication