HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

Smart Array v2.7
1-4-12 HP_DeviceIndication: Controller Battery status
changed to Failed
Table 1-110
HP_DeviceIndication: Controller Battery status changed to Failed
Property name
Property implementation
SolutionProductModel
Conditional property containing the Solution Name string when
running in a aggregate product environment in the format
<aggregate product family name> v<major>.<minor>.<update>
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
Smart Array P400 Embedded Controller=7” for
embedded controller where 7 is the internal identifier
for the embedded controller
HWManufacturer
Array Controller Manufacturer string
HWSerialNumber
Array Controller Serial Number
VariableNames[] FailureDescription
CacheSizeTotal
CacheSerialNumber
VariableTypes[] String (1)
uint32 (5)
VariableValues[] FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
1-4-13 HP_DeviceIndication: Controller Cache Status - OK
Table 1-18 HP_DeviceIndication: Controller Cache status changed to OK
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Info)
IndicationTime
Time of indication