HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

Smart Array v2.7
1-4-10 HP_DeviceIndication: Controller Battery Status
Change - OK
Table 1-108
HP_DeviceIndication: Controller Battery Status Change - OK
Property name
Property implementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
Smart Array P400 Embedded Controller=7” for
embedded controller where 7 is the internal identifier
for the embedded controller
HWManufacturer
Array Controller Manufacturer string
HWSerialNumber
Array Controller Serial Number
VariableNames[] FailureDescription
CacheSizeTotal
CacheSerialNumber
VariableTypes[] String (1)
uint32 (5)
VariableValues[] FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
1-4-11 HP_DeviceIndication: Controller Battery status
changed to not fully charged
Table 1-109 HP_DeviceIndication: Controller Battery status changed to not fully charged
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication