HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Smart Array v2.7
1-4-6 SMX_SAStorageVolumeIndication: Logical Drive
Status Changed to ERROR
Table 1-104
SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR
Property name
Property implementation
DeviceOperationalStatus Current OperationalStatus values for Storage Volume
DeviceOperationalStatus[0]:
SMX_SAStorageVolume.OperationalStatus[0]
DeviceOperationalStatus[1]:
SMX_SAStorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume
DeviceOperationalStatusPrevious[0]:
SMX_SAStorageVolume.OperationalStatus[0]
DeviceOperationalStatusPrevious[1]:
SMX_SAStorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
1-4-7 SMX_SAStorageVolumeIndication: Logical Drive
Status Changed to Degraded
Table 1-105 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3(Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description A logical drive is in a degraded state, Device is still
servicing I/O but redundancy may be degraded or lost
AlertingMangedElement
WBEM Path of SMX_SAStorageVolume Class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
103