HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Smart Array v2.7
1-4-6 SMX_SAStorageVolumeIndication: Logical Drive
Status Changed to ERROR
Table 1-104
SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR
Property name
Property implementation
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain 3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
NOTE: When ImpactedDomain is 3 (Enclosure) the
properties indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWLogicalLocation Logical drive number and RAID Level for example
LogicalDrive 1 (Raid 1+0)
VariableNames[]
FailureDescription
VariableTypes[]
String (1)
VariableValues[]
FailureDescription short description of the failure
HP_DeviceIndication
SMX_StorageVolumeIndication