HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

Smart Array v2.7
1-4-4 HP_DeviceIndication: Physical Drive Status
Changed to PREDICTIVE FAILURE
Table 1-102
HP_DeviceIndication: Physical Drive Status Changed to PREDICTIVE FAILURE
Property name
Property implementation
VariableTypes[] String (1)
uint16 (4)
VariableValues[] FailureDescription short description of the failure
Drive interface HPSA_DiskDrive.DriveInterface
LastFailureDescription last failure reason string from
the drive. HPSA_DiskDrive.OperationalStatus[1]
HP_DeviceIndication
DeviceModel
Physical Disk Model string
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
Smart Array P400 Embedded Controller=7” for
embedded controller where 7 is the internal identifier
for the embedded controller
1-4-5 HPSA_StorageVolumeIndication: Logical Drive
Status Changed to OK
Table 1-103
HPSA_StorageVolumeIndication : Logical Drive Status Changed to OK
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Informational)
IndicationTime
Time of indication
CIM_AlertIndication
Description A logical drive status has changed from a non OK
state to OK
AlertingMangedElement
WBEM Path of SMX_SAStorageVolume
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
101
EventTime Time of the event or time of the indication if event time
unknown