HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

Smart Array v2.7
1-4-2 HP_DeviceIndication: Physical Drive Status
Changed to ERROR
Table 1-100
HP_DeviceIndication: Physical Drive Status Changed to ERROR
Property name
Property implementation
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity Severity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
Physical drive status has changed to Error
AlertingMangedElement
WBEM Path of SMX_SADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
202
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical Drive status is now Error
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
Physical Drive Status Changed to Error
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
OSType
SMX_OperatingSystem.OSType
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion
For example 2.2.0.0
SystemFirmwareVersion Firmware version of the computer system generating
the indication