HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Smart Array v2.7
Table 1-33 Class: SMX_SAStorageCapabilities (CIM_StorageCapabilities)
Property name
Property implementation
ElementName For Primodial Pools: Controller name and location
Examples:
•
Smart Array in Slot=3, for internal
•
Smart Array Embedded Contoller=7 for embedded
controller where 7 is the internal identifier for the
embedded controller
For Concrete Pools: Controller name and
location:Array identifier
Examples:
•
Smart Array in Slot=3: Array – 0, for internal
•
Smart Array Embedded Controller=7: Array -
0” for
embedded controller where 7 is the internal
identifier for the embedded controller
CIM_Capabilities
InstanceID
Key: Opaque key
CIM_StorageCapabilities
DataRedundancyDefault 1—When number of drives is an odd number)
2—When number of drives is an even number (For
example, pool can be configured for mirroring.)
DataRedundancyMax 1—When number of drives is an odd number
2—When number of drives is an even number (For
example, Pool can be configured for mirroring.)
DataRedundancyMin
1
DeltaReservationDefault
0
DeltaReservationMax
0
DeltaReservationMin
0
ElementType
5 (Storage Pool)
NoSinglePointOfFailure True—When number of drives > 1 (For example, pool
can be configured for redundancy.)
False—When number of drives <= 1
NoSinglePointOfFailureDefault True—When number of drives > 1 (For example, pool
can be configured for redundancy.)
False—When number of drives <= 1
PackageRedundancyDefault 0 (When number of drives <= 1)
1 (When number of drives = 2 or 3)
2 (When number of drives > 3)
PackageRedundancyMax 0 (When number of drives <= 1)
1 (When number of drives = 2 or 3)
2 (When number of drives > 3)
PackageRedundancyMin
0
HPSA_StorageCapabilities