HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

Smart Array v2.7
Table 1-20 Class: SMX_SAStoragePool (CIM_StoragePool)
Property name
Property implementation
InstanceID
Opaque key
PoolID Controller serial number:<n>, where <n> is the array
number as supplied from API
Primordial
Always set to FALSE
RemainingManagedSpace
Remaining raw space in current pool
TotalManagedSpace
Total raw space managed by this pool
HPSA_StoragePool
1-3-20 SMX_SAMediaAccessStatData
SMX_SAMediaAccessStatData implements the HPSA_MediaAccessStatData and represents the
Monitoring and Performance data counters on HP Disk Drives.
Table 1-21 SMX_SAMediaAccessStatData (CIM_MediaAccessStatData)
Property name
Property implementation
CIM_ManagedElement
CIM_StatisticalData
InstanceID
Opaque key
SampleInterval
00000000000000.000000:000
CIM_MediaAccessStatData
HPSA_MediaAccessStatData
AbortedCommands
See HP Smart Array Profile
BadTargetErrors
See HP Smart Array Profile
DRQTimeOuts
See HP Smart Array Profile
ECCRecoveredReadErrors
See HP Smart Array Profile
ElementName
Disk location (For example, Port: 1E Box 1 Bay: 5)
FailedReadRecovers
See HP Smart Array Profile
FailedWriteRecovers
See HP Smart Array Profile
FormatErrors
See HP Smart Array Profile
HardReadErrors
See HP Smart Array Profile
HardwareErrors
See HP Smart Array Profile
HardWriteErrors
See HP Smart Array Profile
HotPlugCount
See HP Smart Array Profile
MediaFailures
See HP Smart Array Profile
NotReadyErrors
See HP Smart Array Profile