HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Smart Array v2.7
Table 1-12 Class: SMX_SAStorageEnclosureProcessor (CIM_ComputerSystem)
Property name
Property implementation
OperationalStatus[0,1, 2, 3 ] Operational status for enclosure and associated power
supplies, fans, and sensors.
The use of OperationalStatus is described in the HP
Storage Enclosure Profile. Index values are populated
as follows:
•
Index[0]—Enclosure status:
○ 0 (Unknown)
○ 2 (OK)
○ 3 (Degraded)
○ 6 (Error)
•
Index[1]—Fan status (See Profile)
•
Index[2]—Power Supply status (See Profile)
•
Index[3]—Temp Sensor Status (See Profile)
Note: Operational status for Fan, Power and Temp
Sensor is “not detected” for internal storage
enclosure(s) of the local controller(s), for example, PCI
or Embedded
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_System
CreationClassName
SMX_SAStorageEnclosureProcessor
Name
Opaque Key
NameFormat
Other
CIM_ComputerSystem
Dedicated[0]
2 (Other)
IdentifyingDescriptions[0]
Other Vendor Specific Name
OtherDedicatedDescriptions[0]
SDE—Indicates Storage Device Enclosure
OtherIdentifyingInfo[0] Port Number:BoxNumber enclosure is attached to
1E:1
HPSA_StorageEnclosureProcessor
1-3-12 SMX_SAPortController
SMX_SAPortController HPSA_PortController class and represent the HBA in the host system. There is
one instance per HBA.