HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 September 2013 Datasheets

Table Of Contents
HP Insight Management Power Supply Provider Overview 29
Property Name
Property Implementation
RecommendedActions
No action is recommended.
HP_AlertIndication
Summary
Power supply inserted
EventCategory
16 (System Power)
ProbableCause
1 (Other)
ProbableCauseDescription
Power Supply has been Inserted
1-3-5 HP_DeviceIndication: Power Supply Failed
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
A power supply has failed. PowerSupplyCaption
Where: PowerSupplyCaption is the
SMX_PowerSupply.Caption for the power supply that has failed.
AlertingManagedElement
WBEM Path of SMX_PowerSupply instance representing the failed
power supply.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
3
ProviderName
HP Power