HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U1 OS April 2013 Datasheets

HP Insight Management WBEM Smart Array Provider 100
Property Name
Property Implementation
DeviceControllerLogicalLocation
Controller Location
For example:
SmartArray 642 in Slot 2
1-3-6 HPSA_StorageVolumeIndication : Logical Drive Status
Changed to OK
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Informational)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive status has changed from a non-OK
state to OK.
AlertingManagedElement
WBEM Path of SMX_SAStorageVolume Class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
101
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array