HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U1 OS April 2013 Datasheets
HP Insight Management WBEM Smart Array Provider 85
Property Name
Property Implementation
running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion
Physical Disk firmware version string
HWLogicalLocation
Physical Disk Location string
For example:
Port:1E Box: 1 Bay 5
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
HWSerialNumber
Physical Disk Serial Number
HP_DeviceIndication
DeviceModel
Physical Disk Model string
DeviceControllerLogicalLocation
Controller Location
For example:
SmartArray 642 in Slot 2
VariableNames[]
FailureDescription
DriveInterface
LastFailureDescription
VariableTypes[]
String (1)
uint16 (4)
VariableValues[]
FailureDescription – short description of the failure
Drive interface HPSA_DiskDrive.DriveInterface
LastFailureDescription – last failure reason string from
the drive. HPSA_DiskDrive.OperationalStatus[1]