HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 September 2012 Datasheets
HP Insight Management Power Supply Provider Overview 9
Property Name
Property Implementation
RedundancyStatus
0 (Unknown) – if the redundancy status is unknown;
2 (Fully Redundant) – if the all power supplies in the set are operating properly
and enough to achieve redundancy;
3 (Degraded Redundancy) – if there are at least enough power supplies for the
redundancy set to provide power, but power supplies have failed;
4 (Redundancy Lost) – if there are not enough power supplies required to
achieve redundancy, but enough for the redundancy set to provide power;
5 (Overall Failure) – if there are not enough power supplies operating properly
for the redundancy set to provide power.
1-2-4 SMX_MemberOfPowerRedundancy Class
The SMX_MemberOfPowerRedundancy class is used to represent an association between
HP_PowerSupply and HP_PowerRedundancySet.