HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 October 2012 Profiles

Version 1.0.0
15
10 CIM Elements
The implementation requirements for the classes properties described in this section are described in the
“Implementation Requirements” section (see section 10).
Table 4 CIM Elements HP CPU Physical Asset Profile
Element Name
Requirement
Description
Classes
HP_ProcessorChip
Mandatory
See Section 7.1 and 10.1
HP_RegisteredProfile
Mandatory
See section 10.2
HP_RealizesProcessor
Mandatory
See section 7.3
HP_PhysicalCacheMemory
Optional
See section 7.2
HP_RealizesProcessorCache
Conditional
See section 7.4
HP_SystemPhysicalProcessor
Mandatory
See section 10.3
Indications
None defined
10.1 HP_ProcessorChip
HP_ProccessorChip is used to represent a physical processor chip in a managed system.
Table 5 – Class: HP_ProcessorChip
Properties
Requirement
Notes
ProcessorChipRevision
Optional
See section 7.1.1
10.2 HP_RegisteredProfile
The implementation shall implement an instance of the HP_RegisteredProfile in the Interop namespace
with the values specified.
Table 6 – Class: HP_RegisteredProfile
Properties
Requirement
Notes
RegisteredOrganization
Mandatory
Other (1)
OtherRegisteredOrganization
Mandatory
“HP WBEM TC”
RegisteredName
Mandatory
“HP CPU Physical Asset”
RegisteredVersion
Mandatory
“1.0.0”
10.3 HP_SystemPhysicalProcessor
HP_SystemPhysicalProccessor
is used to represent the association between
HP_ComputerSystemChassis
and HP_ProccesorChip.