HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 October 2012 Datasheets
HP Insight Management WBEM System Memory Provider 34
Property Name
Property Implementation
HP_AlertIndication
Summary
Memory module has failed or is predicted to fail
EventCategory
3 (Memory)
ProbableCause
1 (Other)
ProbableCauseDescription
Memory Module Failed or Predicted to Fail
1-3-3 SMX_MemoryIndication: Memory Board Error
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
A memory board has an error. (MemoryBoardCaption)
Where: MemoryBoardCaption is the SMX_MemoryBoard.Caption for
the failing memory board.
AlertingManagedElement
WBEM Path of SMX_MemoryBoard instance representing the memory
board
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
2
ProviderName
HP Memory
RecommendedActions
Check the memory configuration and replace the memory
board and memory modules as necessary.