HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 October 2012 Datasheets

HP Insight Management WBEM Smart Array Provider 135
Property Name
Property Implementation
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Subsystem status has changed
to non-redundant.
AlertingManagedElement
WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
301
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the indication
HP_AlertIndication
Summary
Power Supply status Non-Redundant
EventCategory
17 (Primary Storage Power)
ProbableCause
89 (Power Supply Failure)
ProbableCauseDescription
Redundant Power Supply Status Changed to Non-Redundant
NetworkAddresses
Contains a list of all the IP addresses of the computer system generating
the indication