HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 October 2012 Datasheets
HP Insight Management WBEM Smart Array Provider 90
Property Name
Property Implementation
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed to
Predictive Failure.
AlertingManagedElement
WBEM Path of SMX_SADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
204
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array (
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary
Physical drive status Predictive Failure.
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
Physical Drive Status Changed to Predictive
Failure.
NetworkAddresses
Contains a list of all the IP addresses of the computer system