HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 October 2012 Datasheets
HP Insight Management Power Supply Provider Overview 8
Property Name
Property Implementation
CIM_ManagedElement
Caption
Short description of this redundancy set.
For example:
Power Redundancy Set <n>
Where:
<n> represents the number of the redundancy set instance.
Description
Description of this redundancy set
For example:
Power Redundancy Set <n> is collection of fault tolerant power supplies
that provide redundant power
Where: <
n> represents the number of the redundancy set instance.
ElementName
User printable name for this power redundancy set.
For example:
Power Redundancy Set <n>
Where: <
n> represents the number of the redundancy set instance.
CIM_SystemSpecificCollection
InstanceID
Unique identifier for this power redundancy instance.
CIM_RedundancySet
MaxNumberSupported
Represents the maximum number of power supplies supported for this
redundancy set.
MinNumberNeeded
Represents the minimum number of power supplies needed to function.
TypeOfSet
3 (Load Balanced)
LoadBalanceAlgorithm
0 (Unknown)