HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 October 2012 Datasheets

HP Insight Management Power Supply Provider Overview 5
Property Name
Property Implementation
HealthState
5 (OK) if power supply is operating properly;
10 (Degraded) if power supply is degraded
20 (Major Failure) if power supply has failed
Name
Unique name of this power supply from the name displayed by the MP or
iLO and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
TimeOfLastStateChange
Time that state last changed for power supply.
0
if it has not changed since
provider startup.
CIM_LogicalDevice
CreationClassName
SMX_PowerSupply
DeviceID
Unique identifier for this power supply instance.
SystemCreationClassName
SMX_ComputerSystem.CreationClassName
SystemName
SMX_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault
2
(Enabled)
EnabledState
5
(Not Applicable)
RequestedState
12
(Not Applicable)
CIM_PowerSupply
TotalOutputPower
Power reported in Milliwatts .The value 0 denotes ‘unknown’
output power.
HP_PowerSupply