HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 October 2012 Datasheets

HP Insight Management Power Supply Provider Overview 4
Property Name
Property Implementation
the value of StatusDescriptions[0]and StatusDescription[1].
ElementName
Short description of this power supply for the name displayed by the MP or
iLO and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) if power supply is operating properly;
3 (Degraded) if power supply is degraded;
6 (Error) if power supply has failed
OperationalStatus[1]
Extended Warning and Error status. See the MOF and Profile
StatusDescriptions[0]
Description of the status of the power supply corresponding to the
OperationalStatus.
For example:
Power Supply is operating properlyif OperationalStatus[0]
is 2 (OK);
Power Supply is degradedif OperationalStatus[0] is 3
(Degraded)
Power Supply has failedif OperationalStatus is 6 (Error)
StatusDescriptions[1]
Description of the extended warning/error status corresponding to the
OperationalStatus[1]. See Profile.