HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet
HP Insight Manager WBEM System Fan Provider Overview 453
Property Name Property Implementation
SystemGUID
Platform GUID of the computer system generating the indication.
SystemVirtualUUID[]
If Synergy is enabled, this will contain the logical UUID for the
system.
SystemVirtualSerialNumber[]
If Synergy is enabled, this will contain the logical Serial Number
for the system.
EnclosureName HP_BladeEnclosureCS.Name
RackName
Rack name, if one exists
RackUUID
Rack Unique Identifier, if one exists
BladeName HP_ComputerSystem.Name
BladeBay HP_BladeCSLocation.LocationInformation[0]
The following indications are implemented for Proliant server platforms where available. System Fan
indications are described below.
HP_DeviceIndication: Fan Removed
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description
A fan has been removed <Fan>
Where: <Fan> is the fan number that was removed.
AlertingManagedElement
WBEM Path of the SMX_Fan instance.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 1
ProviderName HP Cooling
RecommendedActions
Check the fan configuration and ensure that this fan
was removed intentionally.
HP_AlertIndication
Summary Fan removed
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription Fan Removed