HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 364
Property Name Property Implementation
ElementName
RAID <n>
Where: <n> is the RAID Description.
For example: RAID 0
For example: RAID 1+0
For example: RAID 5
For example: RAID 6
CIM_SettingData
InstanceID
Opaque key
CIM_StorageSetting
ChangeableType
0 (Not Changeable)
DataRedundancyGoal
1 (RAID 0, RAID 4, RAID 5, RAID 6, RAID 50, RAID 60)
2 (RAID 1, RAID 1+0, RAID 5+1)
DataRedundancyMax
1 (RAID 0, RAID 4, RAID 5, RAID 6, RAID 50, RAID 60)
2 (RAID 1, RAID 1+0, RAID 5+1)
DataRedundancyMin
1 (RAID 0, RAID 4, RAID 5, RAID 6, RAID 50, RAID 60)
2 (RAID 1, RAID 1+0, RAID 5+1)
DeltaReservationGoal 0
DeltaReservationMax 0
DeltaReservationMin 0
NoSinglePointOfFailure
False – RAID 0
True – RAID 1+0, RAID 5, RAID 6, RAID 50, RAID 60
PackageRedundancyGoal
0 (RAID 0)
1 (RAID 1, RAID 1+0, RAID 4, RAID 5, RAID 6,)
2 (RAID 6, RAID 50, RAID 60)
PackageRedundancyMax
0 (RAID 0)
1 (RAID 1+0, RAID 5, RAID 5+1)
2 (RAID 6, RAID 50, RAID 60)
PackageRedundancyMin
0 (RAID 0)
1 (RAID 1, RAID 1+0, RAID 4, RAID 5, RAID 5+1)
2 (RAID 6, RAID 50, RAID 60)
HPSA_StorageSetting