HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM Ethernet 107
Property Name Property Implementation
Antecedent
ref:SMX_ComputerSystem
Dependent
ref:SMX_EthernetCollection
CIM_HostedDependency
CIM_HostedCollection
HP_EthernetGroupHostedCollection
SMX_EthernetTeam
SMX_EthernetTeam models Ethernet Redundancy Sets (Ethernet Teams).
NOTE:
Currently not implemented on on VMware ESXi platform.
Property Name Property Implementation
CIM_ManagedElement
Caption
Device Name
For example:
HP Network Team #1
Description
Local Area Connection
For example:
Local Area Connection #10
ElementName
Same as caption.
CIM_Collection
CIM_SystemSpecificCollection
Key:InstanceId
System GUID for the team.
CIM_RedundancySet
LoadBalanceAlgorithm
0 (None)
1 (Other)
3 (Round Robin)
MaxNumberSupported
Number of ports configured in team.
MinNumberNeeded
1
OtherLoadBalanceAlgorithm
When LoadBalanceAlgorithm is 1 (Other), OtherLoadBalanceAlgorithm
is set to configured Load Balance Algorithm.
For example:
Automatic
RedundancyStatus
2 (Fully Redundant)
3 (Degraded Redundancy)
4 (Redundancy Lost)
5 (Overall Failure).
TypeOfSet
2 (N+1)
3 (Load Balanced).
HP_GroupRedundancySet