HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0U1 October 2012 Profiles
Version 2.1.0 31
9.5 Disk Sparing - Drive failure example
The following sections describe the implementation of Disk Sparing for SAS HBA controllers.
9.5.1 Before drive failure
HPSAS
_
StorageExtent:
001
OPStatus
=
“OK”
HPSAS
_StorageExtent:
003
OPStatus = “OK”
HPSAS
_StoragePool
:
1
Concrete Pool
ConcreteComponent
ConcreteComponent
HPSAS_
StorageRedundancySet:
A
MemberOfCollection
MemberOfCollection
HPSAS_
StorageExtent:
004
Spare
OPStatus = “OK”
IsSpare
HPSAS
_StorageVolume
:100
OpStatus
= “OK”
AllocatedFromStoragePool
Figure 14 - HP SAS HBA profile: Disk sparing – Pre failure
Figure shows a three drive raid set with one spare drive. OperationalStatus for all the drives and the
storage volume are “OK”. The data drives can be identified by their MemberOfCollection association to
the StorageRedundancySet instance. The spare drive can be identified by its IsSpare association to the
StorageRedundancySet.