HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0U1 October 2012 Profiles

28 2.1.0
Table 12Class: HP_MemoryBoard
Properties Requirement Notes
Tag Mandatory
Key: “HPQ:<provider name>:<unique
ID>” where <provider name> is the name
of the provider that implements this class
and <unique ID> is a unique value for the
instance.
Locked Optional See section 7.8.2
NumberOfSockets Optional See section 7.8.3
AvailableMemory Optional See section 7.8.4
TotalMemory Optional See section 7.8.5
10.9 HP_RealizesMemoryModule
HP_RealizesMemoryModule extends the class CIM_Realizes in ways that are specific to HP memory
implementation.
Table 13Class: HP_RealizesMemoryModule
Properties Requirement Notes
Antecedent Mandatory Key: References HP_MemoryModule
Dependent Mandatory Key: References HP_Memory
10.10 HP_MemoryModuleInSlot
HP_MemoryModuleInSlot extends the class CIM_ElementInConnector in ways that are specific to HP
memory implementation.
Table 14Class: HP_MemoryModuleInSlot
Properties Requirement Notes
Antecedent Mandatory Key: References HP_MemoryModuleSlot
Dependent Mandatory Key: References HP_MemoryModule
10.11 HP_MemoryBoardInSlot
HP_MemoryBoardInSlot extends the class CIM_PackageInConnector in ways that are specific to HP
memory implementation.