HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 September 2012 Data sheets

HP Insight Management WBEM System Memory Provider 10
Condition
OperationalStatus[0]
OperationalStatus[1]
StatusDescriptions[0
]
StatusDescriptions[1]
Memory module status is
unknown
0 (Unknown)
<not populated>
Unknown
<not populated>
Memory module is
operating properly
2
(OK)
<not populated>
OK
<not populated>
Memory module is present
but is not currently used by
the operating system
2 (OK)
15 (Dormant)
OK
Memory module status: Memory present
but not in use
Memory module has
correctable errors
exceeding the condition for
pre-failure warranty
3
(Degraded)
5
(Predictive Failure)
Degraded
Memory module status: Correctable
error threshold for pre-failure
warranty has been exceeded
1-2-4 SMX_MemoryBoard Class
The SMX_MemoryBoard class represents a physical memory board on HP servers. There is an instance of
this class for each memory module present in the system; empty memory module sockets are not
instantiated.
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Physical Memory
<physical location>
.
Refer to “Physical Location for more information.
CIM_ManagedSystemElement