HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 September 2012 Data sheets

HP Insight Management WBEM Smart Array Provider 140
Property Name
Property Implementation
HP_HardwareIndication
HWLogicalLocation
Enclosure Location string
For example:
Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
1-3-19 HP_DeviceIndication: Enclosure Power Supply Status
changed to Redundant Degraded
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Subsystem status has changed
to Degraded Redundancy.
AlertingManagedElement
WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
303