HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 September 2012 Data sheets
HP Insight Management WBEM Smart Array Provider 90
Property Name
Property Implementation
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed to
Predictive Failure.
AlertingManagedElement
WBEM Path of SMX_SADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
204
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array (
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary
Physical drive status Predictive Failure.
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
Physical Drive Status Changed to Predictive
Failure.
NetworkAddresses
Contains a list of all the IP addresses of the computer system