HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 October 2012 Datasheets
HP Insight Mana gement WBEM Sys tem Me mory Provide r 36
Property Name
Property Implementation
the failing memory board.
AlertingManagedElement
WBEM Path of SMX_MemoryBoard instance representing the memory
board
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
2
ProviderName
HP Memory
RecommendedActions
Check the memory configuration and replace the memory
board and memory modules as necessary.
HP_AlertIndication
Summary
Memory board error
EventCategory
3 (Memory)
ProbableCause
1 (Other)
ProbableCauseDescription
Memory Board Error
1-3-4 SMX_MemoryIndication: Memory Redundancy Degraded
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
The Advanced Memory Protection (AMP) system is
operating with degraded redundancy. The targeted
configuration has degraded or is operating with memory
modules that have failed or predicted to fail.