HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 October 2012 Datasheets

HP Insight Mana gement WBEM Sys tem Me mory Provide r 19
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Memory Modul e Socket Location <physical location>.
Refer to Physical Location for more information.
Description
Memory Modul e Socket Location <physical location>.
Refer to Physical Location for more information.
ElementName
Memory Modul e Socket Location <physical location>.
Refer to Physical Location for more information.
CIM_Location
Name
Opaque key of the format:
HPQ:SMX_MemoryModuyleSlotLocation:<Key 1>: <Key 2>: ...etc.
PhysicalPosition
Opaque key.
Example for memory
socket number 2 on cpu, board, or cartridge number 1:
FF-FF-FF-FF-01-02-FF-79
HP_Location
ElementLocationTag
Opaque key.
Example for memory socket number 2 on cpu, board, or cartridge number 1:
FF-FF-FF-FF-01-02-FF-79
ElementLocationTagDesc
8 (Memory Modul e)
LocationInformation
Indexed array: LocationInformation[0]
per LocationInformationDesc[0].
Location information will contain a numeric string representing the unique
location identifier of each object type described by the