HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 October 2012 Datasheets
HP Insight Management WBEM Smart Array Provider 83
Property Name
Property Implementation
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed to Error.
AlertingManagedElement
WBEM Path of SMX_SADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
202
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array (
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary
Physical drive status Error
EventCategory
6
(Primary Storage)
ProbableCause
86
(Disk Failure)
ProbableCauseDescription
Physical Drive Status Changed to Error
NetworkAddresses
Contains a list of all the IP addresses of the computer system
generating the indication