HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 March 2012 Data Sheet

HP Insight Management WBEM System Memory Provider 37
Property Name
Property Implementation
AlertingManagedElement
WBEM Path of SMX_MemoryRedundancySet instance representing the
Memory Redundancy.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
4
ProviderName
HP Memory
RecommendedActions
No action is recommended.
HP_AlertIndication
Summary
Advanced Memory Protection redundancy is now fully
operational
EventCategory
3 (Memory)
ProbableCause
1 (Other)
ProbableCauseDescription
Advanced Memory Protection now Fully Operational
1-4 Physical Location
Memory Physical Location is a string representing the physical location of a Memory device, such as DIMM,
slot, socket, board, or extender. This string should represent the physical location of the device with which
an end-user can uniquely locate the device. Most of these strings will be represented in customer
documentation, silkscreen labels, or hood tags.
The following table lists the properties implemented. Any combination of the following applicable
descriptors could be used to better define the device location.
All Systems
HP Integrity
Cellular Servers
HP BladeServers in
C3000 / C7000
Enclosures
Socket=<num>
Cabinet=<num>
Blade=<num>