HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 March 2012 Data Sheet
HP Insight Management WBEM System Memory Provider 33
Property Name
Property Implementation
SystemVirtualSerialNumber[]
If Synergy is enabled, this will contain the logical Serial Number for
the system.
SolutionProductModel
Conditional property containing the Solution Name string when
running in a aggregate product environment in the format
<aggregate product family name> v<major>.<minor>.<update>
EnclosureName
HP_BladeEnclosureCS.Name
RackName
Rack name, if one exists
RackUUID
Rack Unique Identifier, if one exists
BladeName
HP_ComputerSystem.Name
BladeBay
HP_BladeCSLocation.LocationInformation[0]
1-3-2 SMX_MemoryIndication: Memory Module Predictive
Failure
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
A memory module has failed or is predicted to fail.
(MemoryModuleCaption) where MemoryModuleCaption is
the
SMX_MemoryModule.Caption for the failing memory module
AlertingManagedElement
WBEM Path of SMX_MemoryModule instance representing the memory
module
AlertingElementFormat
2 (CIMObjectPath)