HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 March 2012 Data Sheet

Table 16-73 HP_DeviceIndication: Physical Drive status OK
Property name
Property implementation
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Disk firmware version string
HWLogicalLocation Disk Location string
For example, Bay 3
HWManufacturer
Disk Manufacturer string
HWSerialNumber
Disk Serial Number
HP_DeviceIndication
DeviceModel
Disk Model string
1-2-4 Physical Drive status ERROR
Table 16-74 HP_DeviceIndication: Physical Drive status ERROR
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity Severity
For example, 5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed to Error.
AlertingManagedElement
WBEM Path of disk drive
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
202