HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 March 2012 Data Sheet

HP Insight Management WBEM Management Processor Lite Provider 23
Property Name
Property Implementation
Management Processor NIC Status: NIC disconnected
Management Processor NIC Status: NIC failed
Management Processor NIC Status: NIC is disabled
Management Processor NIC Status: Not in use, MP is
utilizing host NIC
HealthState
0 (Unknown), when OperationalStatus[0]=0 (Unknown)
5 (OK), normal operation
10 (Degraded/Warning), when OperationalStatus[0]=3
(Degraded)
20 (Major failure), when OperationalStatus[0]=6 (Error)
Note:
When a Management Processor is disabled (refer to
property
EnabledState) HealthState will always report a state of 5
(OK) so as not to contribute negatively to overall system status. An MP is
disabled only if the user has manually disabled it via the MP’s RBSU settings
;
this is seen as a normal condition.
CIM_LogicalElement
CIM_EnabledLogicalElement