HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 March 2012 Data Sheet
HP Insight Management WBEM System Memory Provider 34
Property Name
Property Implementation
AlertType
5 (Device Alert)
EventID
1
ProviderName
HP Memory
RecommendedActions
Check the memory configuration and replace memory as
necessary.
HP_AlertIndication
Summary
Memory module has failed or is predicted to fail
EventCategory
3 (Memory)
ProbableCause
1 (Other)
ProbableCauseDescription
Memory Module Failed or Predicted to Fail
1-3-3 SMX_MemoryIndication: Memory Board Error
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5
(Major)
CIM_AlertIndication
Description
A memory board has an error. (MemoryBoardCaption)
Where: MemoryBoardCaption is the SMX_MemoryBoard.Caption for
the failing memory board.
AlertingManagedElement
WBEM Path of
SMX_MemoryBoard
instance representing the memory
board
AlertingElementFormat
2 (CIMObjectPath)