HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 March 2012 Data Sheet
HP Insight Management WBEM System Memory Provider 14
1-2-6 SMX_MemoryModuleSlot Class
The SMX_MemoryModuleSlot class represents memory module slots on HP servers. There is an instance of
this class for each memory module socket in the system (whether the slot is occupied or not).
Note: In the following property implementation descriptions, memory module slots located on the system
board are denoted as being located on board/cartridge number 0.
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Memory Module
<physical location>
.
Refer to “Physical Location” for more information.
CIM_ManagedSystemElement
OperationalStatus
OperationalStatus[0] = 2 (OK)
StatusDescriptions
StatusDescriptions
[0] = Memory module slot status:OK
HealthState
5
(OK)
Name
Memory Module
<physical location>
.
Refer to “Physical Location” for more information.
CIM_PhysicalElement
CreationClassName
SMX_MemoryModuleSlot
Tag
Opaque key of the form: HPQ:SMX_MemoryModuleSlot:
<unique_keys>
Description
Memory Module <physical location>.
Refer to “Physical Location” for more information.
ElementName
Memory Module
<physical location>
.
Refer to “Physical Location” for more information.