HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 March 2012 Data Sheet
HP Insight Management WBEM Smart Array Provider 121
Property Name
Property Implementation
VariableValues[]
FailureDescription – short description of the failure
CacheSizeTotal
HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
1-3-13 HP_DeviceIndication: Controller Battery Status Changed
to FAILED
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Smart Array controller battery status changed to
Failed.
AlertingManagedElement
WBEM Path to SMX_SAArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
8
EventTime
Time of the event or time of the indication if event time unknown