HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 March 2012 Data Sheet

Table 16-87 HP_DeviceIndication: Enclosure Fan status changed to OK
Property name
Property implementation
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
1-2-18 Enclosure Fan status changed to Degraded
Table 16-88
HP_DeviceIndication: Enclosure Fan status changed to Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan status has changed to
Degraded. An enclosure has detected there might be a
problem with one or more of the fans.
AlertingManagedElement
WBEM Path of SMX_SASStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
305
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Fan status Degraded
EventCategory
24 (Primary Storage Cooling)