HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 March 2012 Data Sheet
Table 16-77 HP_DeviceIndication: Drive status PREDICTIVE FAILURE due to SSD Wear out
Property name
Property implementation
HWManufacturer
Disk Manufacturer string
HWSerialNumber
Disk Serial Number
HP_DeviceIndication
DeviceModel
Disk Model string
1-2-8 Logical Drive status OK
Table 16-78 HP_DeviceIndication: Logical Drive status OK
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Informational)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive status has changed from non-OK to OK.
AlertingManagedElement
WBEM Path of Storage Volume
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
101
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
No action is recommended.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Logical Drive status OK
EventCategory
6 (Primary Storage)
ProbableCause
1 (Other)
ProbableCauseDescription
Logical Drive Status Changed to OK
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses List of all the IP addresses of the computer system
generating the indication