HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 March 2012 Data Sheet

Table 16-76 HP_DeviceIndication: Drive status PREDICTIVE FAILURE
Property name
Property implementation
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Predictive
Failure.
AlertingManagedElement
WBEM Path of disk drive
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
204
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive predictive failure
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
Physical Drive Predictive Failure
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
On ESXi, 39 (VM)
On Linux, 36 (Linux)
OSVersion The operating system version of the computer system
generating the indication in the following
format: <major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication